Type Code: Q8-UV3 

+Standard: 

The product can be designed by following the Standard of GB/T 14522-93(China National Standard of Accelerated Aging Test), ASTM G154D4587-91,ISO 11507/4892-3NE 927-6 etc.

+Power: AC 220V-50HZ-13wire-25A (voltage error should be less than 10%)

+Technical Parameters:

Effective Radiation Range

900×210mm (W×H)   

Light Center Distance 

70mm        

Wavelength Range

UVA-340:315~400nm

Radiation Intensity 

Adjustable within 1.0w/ m2/340nm

Temperature Accuracy 

0.1

UV Light Temperature Range

50~70/Acceptable Error±3

Water Spray Temperature Range

40~60/Acceptable Error±3

Temperature Control  

PID Self-Adjust 

Humidity Range 

45%~98%R.H

Water Sink

Water Depth less than 25mm (automatic control)

Environment Of Placing Tester

5~3545%~85%R.HAway from the wall 300mm

Samples Away from UV light 

50mm

+Main Principle:

-Q8-UV3 Accelerated Aging Tester adopts fluorescent UV light UVA-340 and the water-spray system in order to imitate the damage of sunlight, rain, humidity etc. 

The samples is under UV radiation damage and the water spray damage circularly.The damage intensity would be more than 1o times of the damage in the natural environment. 

-The damage is like: fading, changing color, delamination, haze, bubbles, embrittlement , aging, oxidation etc.

+Sample Self 

-Samples Dimension:75×150mm, Maximum Thickness:20mm (Customization is available)

-Samples Quantity :About 24 pieces at one time (for reference)

 

+UV light :

-There are 8 UV lights installed inside the tester.

-Two type of UV light for option: UVA-340 and UVB-313

-UVA-340spectral radiation intensity focus on 340nm wavelength 

-UVB-313 spectral radiation intensity focus on 313nm wavelength 

-Uselife cycle of the UV light: 18002500hours 

-Because the radiation intensity is becoming weak after using, so after the 25% of the uselife circle, please replace one of the "old UV light " by "non-used UV light", then the Radiation Intensity will be constant. 

+Black Board:

-Temperature Deviation of different pieces of test samples:≤4% (the temperature is even on the surfaces of the samples

-Temperature Inspector:Pt-100 Sensor(±2.0℃) (Accurately inspecting the temperature)

-Temperature range:40-93℃±10%

+Water Control:

-Water vapour reaches the code face of samples and become water.

-Water Sink Temperature Range :40~60℃

+Timing Control 

 Timing range: 0~9999H(including cumulative function and Memory when power lose unexpectedly  )

+Security

-If the temperature is oven 93℃±10%, the system will shut off the Light and Heater and start to cool.

-Water Sink Alarm.

+Tester Machine Size

-External Dimension:H1550mm×W1350mm×D510 mm

Notes:Protruded Parts is not counted into the Dimension.